Fuse Rating Calculator

Work out a sensible primary mains fuse rating from your transformer's total VA, or build it up from each secondary winding.

From Transformer VA

If your transformer is rated in total VA (volt-amps), this is the quickest route to a fuse value.

VA
Recommended primary fuse
2 A
calculated draw: 1.0 A

Slow-blow (time-delay) fuses tolerate the brief inrush from transformer magnetization, tube heater cold-resistance, and filter cap charging — that's why the headroom above is modest. A fast-blow fuse in this spot would need much more headroom and likely nuisance-trip anyway.

From Individual Windings

No VA rating on hand? Build up the total from each winding's voltage and expected current draw — typically the HT (B+) secondary and one or more heater windings.

WindingVoltage (V)Current (A)
Recommended primary fuse
2 A
total: 0 VA · calculated draw: 0 A

Total VA is just the sum of each winding's V×I. This treats the transformer as roughly lossless for sizing purposes, which is the same assumption most amp schematics make when they quote a single VA figure.